Crown FM250 Manuale Utente Pagina 19

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 38
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 18
3–4
FM10000 Users Manual
3.3 Front Panel Controls and Display
Refer to illustration 3-1 for additional information when going through section 3.3.
3.3.1 Remote/Local Switch
The Remote/Local switch is used to be able to 'break' the interlock line from the 
remote control unit to allow for local control of the High Voltage supply that 
feeds the PA's. It has a green LED which illuminates when the switch is in the 
remote position (allowing for control via remote control unit) and a red LED 
which will illuminate when the switch is in the local position (disabling the 
remote control from turning on the high voltage). See illustration 3-3.
Illustration 3-3 Remote/Local and Local Enable switches with indicators
3.3.2 Local Enable Switch
The Local Enable Switch is used to enable the high voltage supply for the PA's 
when the Transmitter Controller is in the 'Local' mode. The switch in the ON 
position (up, or 1) will enable the supplies and illuminate the red indicator 
LED. The switch in the OFF position (down, or 0) will disable the supplies and 
extinguish the red LED. See illustration 3-3.