Operation 3–5
The Transmitter Controller has the ability to internally set the maximum RF output 
power for the 10000 watt system using the power control setting for each PA. These 
controls are located behind the front panel and have an access hole in front of each 
control. A small flat blade screwdriver is needed to adjust each control. For 
maximum output level, these controls need to be set fully Clock-wise. Adjust the 
controls for each PA separately (PA1 thru PA5) in small steps (less than 300 watts 
difference) to prevent any unnecessary VSWR problems to the other amplifiers (the 
ones not being adjusted). These controls will effect the final RF output power that 
the remote control can adjust to. Whatever these are set for as a maximum level, that 
level is all the higher the remote control will be able to set the power to. See 
illustration 3-4 for location of these controls.
Illustration 3–4 Power Control Adjustment location
3.3.4 Raise/Lower RF Power Control
3.3.3 Transmitter RF Power Control
The Transmitter Controller has the ability to Raise or Lower the RF Power in 
small increments using the control switches on the front panel. Refer to 
illustration 3-4 for the location of these controls. To raise the power, depress 
the switch under the "Raise" label. Press and hold this switch to change the 
power in 200 watts/second increments. Pressing once should only change the 
power 20 - 30 watts. To lower the power, depress the switch under the "Lower" 
label. Press and hold this switch to change the power in 200 watts/second 
increments. Pressing this switch once will change the power 20 - 30 watts. 
Both switches are momentary contact type switches and parallel the remote 
control for Raising and Lowering power via Port A on the back of the unit. A 
remote control unit is not required for this operation. These controls will 
change the RF output power on all PA's simultaneously, reducing the need for 
separate controls for each PA.